{"id":643344,"date":"2013-02-21T08:30:59","date_gmt":"2013-02-21T13:30:59","guid":{"rendered":"http:\/\/www.datacenterknowledge.com\/?p=91707"},"modified":"2013-02-21T08:30:59","modified_gmt":"2013-02-21T13:30:59","slug":"keep-your-servers-cool-and-your-business-hot","status":"publish","type":"post","link":"https:\/\/mereja.media\/index\/643344","title":{"rendered":"Keep Your Servers Cool, And Your Business Hot"},"content":{"rendered":"<p><i>Gary Bunyan is Global DCIM Solutions Specialist at <a href=\"http:\/\/www.itracs.com\/\">iTRACS Corporation<\/a>, a Data Center Infrastructure Management (DCIM) company. This is the 10th in a series of columns by Gary about \u201cthe user experience.\u201d See Gary\u2019s previous columns on <\/i><em><a href=\"http:\/\/www.datacenterknowledge.com\/archives\/2013\/01\/10\/turning-dcims-big-data-into-actionable-insight\/\">Turning DCIM\u2019s Big Data into Actionable Insight <\/a><\/em><i>and <\/i><em><a href=\"http:\/\/www.datacenterknowledge.com\/archives\/2012\/10\/11\/unlock-your-capacity-by-unplugging-your-ghost-servers\/\">Unlock Your Capacity By Unplugging Your Ghost Servers<\/a><\/em><i>.<\/i><\/p>\n<div class=\"columnist-image\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-71572\" title=\"Gary-Bunyan-sm2\" alt=\"Gary-Bunyan-iTRACS\" src=\"http:\/\/www.datacenterknowledge.com\/wp-content\/uploads\/2012\/05\/Gary-Bunyan-sm2.jpg\" width=\"88\" height=\"114\" \/>GARY BUNYAN<br \/>\niTRACS<\/div>\n<p>With more and more computing resources being deployed in denser and denser data center spaces, it\u2019s no wonder data center professionals are focused on cooling. The data center is now at the epicenter of today\u2019s hottest businesses, essential to their competitive positioning and market success. But no matter how dense the data center gets, its servers, blades, and other IT assets must be kept cool.<\/p>\n<p>Cooling is an expensive necessity in many data centers. Customers \u2013 like the one in the Middle East I was just visiting \u2013 are always looking to provide just the right amount of it.<\/p>\n<p>What\u2019s the \u201cright\u201d amount of cooling? It\u2019s the perfect balance between under- and over-cooling in a consistent flow across all of your assets. Not enough cooling and the servers are at risk. Too much cooling and you\u2019re spending more on energy that you need. Uneven cooling and you get thermal inconsistencies \u2013 areas either too hot or too cold. <i>The right amount of cooling<\/i> \u2013 and you\u2019re running the most efficient infrastructure possible, minimizing both your cooling costs and your risk.<\/p>\n<p>The trick is to use a DCIM solution that offers you live data about thermal conditions at the individual server level, and sends you real-time alerts if a threshold is in potential of being reached. Instead of guessing about server temperatures, DCIM gives you actual inlet and outlet readings at the device level in your dashboards. Armed with this knowledge, you can run a \u201clean machine\u201d that minimizes cooling while keeping your assets safe. This tightrope can only be walked safely if you have real-time information at your fingertips. Guesswork is way too dangerous.<\/p>\n<h3>Beware of Thermal Hot Spots<\/h3>\n<p>Using a DCIM tool with visualization lets you identify, manage and resolve potential hot spot issues on your floor <i>before<\/i> they turn into problems. The key is to be proactive, not reactive. Here&#8217;s how it works:<\/p>\n<p><b>Forensics: Identifying the Source of the Hot Spot<\/b><\/p>\n<p>(1) A thermal hot-spot alert goes off in your DCIM environment. If you\u2019re using a visualization tool, you can instantly see the problem area highlighted in red. The alert is being fed by real-time data from any number of sources depending on your environment \u2013 Intel DCM, Power Assure, RF Code, or other data feeds. With a few clicks, you interrogate the alert and learn that rising temperatures in the top U positions of 3 racks are about to go critical.<\/p>\n<div id=\"attachment_91714\" class=\"wp-caption aligncenter\" style=\"width: 480px\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-91714\" alt=\"Real-time thermal readings indicate an issue.\" src=\"http:\/\/www.datacenterknowledge.com\/wp-content\/uploads\/2013\/02\/iTRACS-1-470.png\" width=\"470\" height=\"235\" \/><\/p>\n<p class=\"wp-caption-text\">Real-time thermal readings indicate an issue.<\/p>\n<\/div>\n<p>(2) You run forensics at the device level, looking at a live data feed of inlet and outlet temperatures from each affected server. You confirm that server inlet\/outlet temperatures have exceeded thresholds.<\/p>\n<div id=\"attachment_91718\" class=\"wp-caption aligncenter\" style=\"width: 480px\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-91718\" alt=\"Inlet\/outlet temps in the server pool have exceeded thresholds.             \" src=\"http:\/\/www.datacenterknowledge.com\/wp-content\/uploads\/2013\/02\/iTRACS-2-470.png\" width=\"470\" height=\"297\" \/><\/p>\n<p class=\"wp-caption-text\">Inlet\/outlet temps in the server pool have exceeded thresholds.<\/p>\n<\/div>\n<p>(3) With a few clicks \u2013 still within the DCIM system \u2013 you review maintenance schedules and reports. You learn that a CRAC unit is still offline, past its scheduled repair window.<\/p>\n<p>(4) With a few more clicks, you interrogate the servers under threat and identify which business unit owns them \u2013 you confirm they are revenue-generating applications with direct impact on profitability. So you must take action immediately.<\/p>\n<p><b>Resolution: Migrating the Applications to a Safer Environment<\/b><\/p>\n<p>(5) Using DCIM\u2019s predictive what-if scenarios, you quickly determine where you can move the applications running on the endangered servers \u2013 you need to migrate them to cooler IT assets with the appropriate power and connectivity.<\/p>\n<p>(6) You confirm your migration strategy in the safety of the DCIM software and give your technicians a clear set of instructions \u2013 complete with automatically-generated 3-D diagrams \u2013 so they know exactly what to do.<\/p>\n<p>(7) You confirm with the business unit and secure approval to move the applications, then dispatch you technical teams to execute the move.<\/p>\n<div id=\"attachment_91719\" class=\"wp-caption aligncenter\" style=\"width: 480px\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-91719\" alt=\" Applications are temporarily moved to safeguard the business until hot-spot is resolved Images courtesy of iTRACS.. \" src=\"http:\/\/www.datacenterknowledge.com\/wp-content\/uploads\/2013\/02\/iTRACS-3-470.png\" width=\"470\" height=\"241\" \/><\/p>\n<p class=\"wp-caption-text\">Applications are temporarily moved to safeguard the business until hot-spot is resolved<br \/>Images courtesy of iTRACS..<\/p>\n<\/div>\n<p>8) Once you\u2019ve confirmed that the CRAC maintenance has been completed and the CRAC unit is back online, you migrate the applications back to the original servers.<\/p>\n<p><b>The Bottom Line \u2013 Uninterrupted Revenue for the Business<\/b><\/p>\n<p>Identifying and resolving hot spot issues is relatively easy when you have the right DCIM tools.\u00a0 And the benefits are quantifiable:<\/p>\n<ul>\n<li><strong>Optimum business continuity<\/strong><i><strong> \u2013<\/strong> <\/i>the organization\u2019s revenue-generating applications continue operating with no impact on customer service or revenue streams.<\/li>\n<li><strong>Uninterrupted service levels<\/strong><i><strong> \u00ad\u2013<\/strong> <\/i>you continue to meet your SLAs.<\/li>\n<li><strong>Mitigating risk associated with maintenance<i> \u2013<\/i><\/strong> you use incident to improve maintenance scheduling and minimize potential future risk to operations.<\/li>\n<\/ul>\n<p><i>See Gary\u2019s previous columns on <\/i><em><a href=\"http:\/\/www.datacenterknowledge.com\/archives\/2013\/01\/10\/turning-dcims-big-data-into-actionable-insight\/\">Turning DCIM\u2019s Big Data into Actionable Insight <\/a><\/em><i>and <\/i><em><a href=\"http:\/\/www.datacenterknowledge.com\/archives\/2012\/10\/11\/unlock-your-capacity-by-unplugging-your-ghost-servers\/\">Unlock Your Capacity By Unplugging Your Ghost Servers<\/a><\/em><i>.<\/i><\/p>\n<p><em>Industry Perspectives is a content channel at Data Center Knowledge highlighting thought leadership in the data center arena. See our <a href=\"http:\/\/www.datacenterknowledge.com\/industry-perspectives-thought-leadership\/\">guidelines and submission process<\/a> for information on participating. View previously published Industry Perspectives in our <a href=\"http:\/\/www.datacenterknowledge.com\/archives\/category\/perspectives\/\">Knowledge Library<\/a>.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Gary Bunyan is Global DCIM Solutions Specialist at iTRACS Corporation, a Data Center Infrastructure Management (DCIM) company. This is the 10th in a series of columns by Gary about \u201cthe user experience.\u201d See Gary\u2019s previous columns on Turning DCIM\u2019s Big Data into Actionable Insight and Unlock Your Capacity By Unplugging Your Ghost Servers. GARY BUNYAN [&hellip;]<\/p>\n","protected":false},"author":7448,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7],"tags":[],"class_list":["post-643344","post","type-post","status-publish","format-standard","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/posts\/643344","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/users\/7448"}],"replies":[{"embeddable":true,"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/comments?post=643344"}],"version-history":[{"count":0,"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/posts\/643344\/revisions"}],"wp:attachment":[{"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/media?parent=643344"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/categories?post=643344"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mereja.media\/index\/wp-json\/wp\/v2\/tags?post=643344"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}